INTRA AORTIC BALLOON PUMP – Meqube https://www.meqube.com Refurbished Medical Equipment Sales and Service Fri, 21 Jan 2022 04:44:36 +0000 en-US hourly 1 https://wordpress.org/?v=6.6.2 https://www.meqube.com/wp-content/uploads/2022/01/cropped-logo-32x32.jpg INTRA AORTIC BALLOON PUMP – Meqube https://www.meqube.com 32 32 MAQUET DATASCOPE CS100 https://www.meqube.com/product/maquet-datascope-cs100/ Wed, 19 Jan 2022 03:39:03 +0000 https://www.meqube.com/?post_type=product&p=468 Features The CS 100 is an Intra-Aortic balloon pump that comes with a one button startup. The Datascope can be customized to fit each individual need. The Maquet Datascope CS100 comes with three different operating modes; Automatic, Semi-automatic and Manual, making it easy to switch from one to the when needed. The Datascope CS100 was designed with a with a fold able and detachable laptop style display and screen making it easier for care givers to adjust the pump and monitor the patient remotely. The full color display shows the balloon waveform and inflation markers making it ideal for Critical Care unit and Operating Rooms.
  • Maquet CS100 IABP comes with with IntelliSync offers one-button start up, automatically adapting to changing conditions, making it the right choice for any patient condition.
  • Automatically evaluates and selects optimal trigger source and lead
  • Sets inflation at the dicrotic notch and deflates IAB at the start of systole
  • Responds to changes in signal quality by selecting new trigger source Automated trigger source and timing management provide continuous, consistent support for your patient.
  • Fast, one-button start-up automatically conducts autofill and initiates 1:1 assist.
  • Full color, high contrast display tilts for easy viewing.
  • Display and keypad in laptop-style configuration, allowing caregivers to fold and detach the unit for remote operation. Easy-to-use keypad with an intuitive user interface.
  • Customizable display panel allows operators to adjust sweep speed, brightness, balloon waveform, and inflation markers.
  • Switch easily between three operation modes: Automatic, Semi-Automatic and Manual.
  • Automatically evaluates and selects optimal trigger source and lead.
  • System detects changes and easily adapts to new patient rhythms.
  • Fully annotated printouts with user-configurable waveforms and strip lengths.
  • Locking casters and durable design keep the CS100 secure in a variety of settings.
]]>

Specifications

Dimensions
  • Height: 30 in (76.2 cm)
  • Width: 22.5 in (57.2 cm)
  • Depth: 13.2 in (33.5 cm)
  • On Cart
    • Height: 42.2 in (114.8 cm)
    • Width: 17.6 in (44.7 cm)
    • Depth: 23.4 in ( 59.4 cm)
  • Off Cart
    • Height: 28.2 in (71.6 cm)
    • Width: 11.3 in (28.7 cm)
    • Depth: 21.5 in ( 54.6 cm)
  • Monitor weight: 9.5 lbs (4.3 kg)
  • Console weight: 133.2 lbs ( 60.4 kg)
Color Display
  • Width:8.3 in (21cm)
  • Height: 6.2 in (15.8 cm)
  • viewing angle:
    • Up: 45°
    • Down 55°
    • Right 70°
    • Left 70°
    • Rotates 330°
    • Tilts180°
  • Detachable Laptop-like closure for storage and protection
Power
  • Mains Voltage: 100-120 VAC ± 10% or 220-240 VAC ± 10%
  • Mains Frequency: 50/60 Hz ± 3 Hz
  • Internal Battery: 24 VDC (nominal), 17.2 Amp-hour, 3 hrs.(approx. @ 90 bpm)
  • Battery Type: Maintenance free; Sealed lead-acid
General information
  • ECG Gain (default): 1 V output per 1 mV input ±5% (waveform automatically scaled to occupy ECG display window)
  • Gain (variable): 0.15 to 3.0 cm/mV ±20% (autoscaling disabled)
  • Frequency Response: 0.5-12 Hz (display); 0.5-135 Hz (Output to Monitor)
  • Defibrillator Protection: Discharge levels 􀀩360 J (trace returns to screen in 5 sec. max)
Operating Conditions
  • Operating Temperature: 10°C – 40°C
  • Operating Humidity: 5 – 95% (R.H.) non-condensing
  • Operating Altitude: 0 – 12,000 feet (3,657 m); automatic altitude correction for IAB pressure
Operating Modes
  • ECG Trigger: Threshold dynamically adjusted by system for high sensitivity and selectivity of the R-wave detection; Minimum = 120μV ± 20μV at normal gain; 40μV at max. gain
  • Pressure Trigger: Default trigger threshold is automatically adjusted to 38% of the difference between peak systolic and end diastolic (avg. over multiple cycles); In variable mode: User adjustable between 7 and 30 mmHg ± 3 mmHg
  • Pacer A Trigger: R-wave detection (as above) except pacer blanking is extended to 100 ms
  • Pacer V/A-V Trigger: V Pacer: fixed at rate up to 185 bpm (no demand pacing) A-V Pacer: fixed at rate up to 125 bpm (no demand pacing) with A-V intervals between 80-224 ms
  • Internal Trigger: Variable mode: 40-120 bpm; Normal mode: 80 ± 1 bpm
  • Tall T-Wave Rejection: Rejects all T-Waves where Q-T interval is <300 ms and the amplitude is <70% of QRS input amplitude
  • Pacer Rejection: Rejects all pulses of amplitude ± 2.0 mV to ± 700 mV and durations between 0.1 ms to 2.0 ms with: 1) No tail; 2) 100 ms time constant tail < 1 mV; 3) 25 ms time constant tail < 1 mV; 4) 4 ms time constant tail < 2 mV
]]>
MAQUET DATASCOPE CS300 https://www.meqube.com/product/maquet-datascope-cs300/ Wed, 19 Jan 2022 03:28:59 +0000 https://www.meqube.com/?post_type=product&p=463 Features The Maquet Datascope CS300 IABP with IntelliSense combines fiber-optic speed with automatic in vivo calibration. The result is a faster time for therapy, faster signal acquisition, and faster adaptation to rate and rhythm changes. Maquet has the only fiber-optic IABP and catheter system that automatically calibrates in the patient after insertion and automatically recalibrates in vivo every two hours or sooner should the patient or environmental conditions change. The CS300 Datascope IABP with INTELLISENSE™ software is designed to emulate an experienced user, allowing you more time to focus on your patient. This sophisticated algorithm automatically selects the best lead and trigger source, sets optimal inflation and deflation timing, and still allows the clinician the ability to fine-tune deflation timing. The Maquet IABP quickly adapts to rate or rhythm changes in order to optimize augmentation and support during diastole.  
  • Faster inflation and deflation speed
  • CS300 has true one-button start-up
  • Automatically calibrates the fiber-optic pressure sensor in the patient and recalibrates every 2 hours or sooner should patient or environmental conditions change
  • Automatically evaluates and selects the best lead and trigger source
  • Automatically sets optimal timing
  • Automatically adjusts to changes in patient conditions without clinician intervention
  • A Maquet fiber-optic IAB catheter
  • Conventional fluid-filled IAB catheters
]]>

Specifications

Dimensions
  • Size on Cart: 43.1” H x 22.3” D x 16.8” W (109 cm H x 56.6 cm D x 42.7 cm W)
  • Size off Cart: 26.9” H x 20.5” D x 10.8” W (68.3 cm H x 52.1 cm D x 27.4 cm W)
  • Console Weight: 84.8 lbs. (38.4 Kg) nominal (includes S.D., CRM, and He tank)
  • Monitor: 9.5 lbs. (4.3 Kg) nominal
  • Hospital Cart Weight: 52.4 lbs. (23.8 Kg) nominal
  • Internal Battery: 34 lbs. (15.4 Kg) nominal
  • Storage Bag: 4.6 lbs. (2.1 Kg) nominal (includes doppler and doppler holder))
Color Display
  • Color TFT Liquid Crystal Display (LCD) 8.3”(21cm)W x 6.2”(15.8cm)H; up 45°, 10.4” diagonal (26.4 cm) down 55°, right 70°, left 70° viewing angle; Rotates 330°; Tilts 180°; Detachable; Laptop-like closure for storage and protection; Remote monitor mount (optional)
Trigger
  • ECG Trigger: Threshold dynamically adjusted by the system for high sensitivity and selectivity of the R-wave detection; Minimum = 120µV ± 20µV at a normal gain; 40µV at max. gain
  • Pressure Trigger: Default trigger threshold is automatically adjusted to 38% of the systolic pulse height; 7 mm minimum
  • Manual threshold mode: User adjustable between 7 and 30 mmHg ± 3 mmHg
  • Pacer A Trigger: R-wave detection (as above) except pacer blanking is extended to 100 ms
  • Pacer V/A-V Trigger: V Pacer: fixed at a rate up to 185 bpm (no demand pacing)
  • A-V Pacer: fixed at a rate up to 125 bpm (no demand pacing) with A-V intervals between 80-224 ms
Power
  • Mains Voltage: 100-120 VAC ± 10% or 220-240 VAC ± 10%
  • Mains Frequency: 50/60 Hz ± 3 Hz
  • Internal Battery: 24 VDC (nominal), 17.2 Amp-hour, approx. 3 hrs. @ 90 bpm
  • Battery Type: Maintenance free; Sealed lead-acid
Pressure
  • Pressure Output: (electrically isolated)
  • Pressure Range: 0 to +300 mmHg (minimum)
Operation
  • Op. Temp.: 10°C – 40°C
  • Op. Humidity: 5 – 95% (R.H.) non-condensing
  • Op. Altitude: 0 – 12,000 feet (3,657 m); automatic altitude correction for IAB pressure
ECG
  • ECG Leads: In Auto Operation Mode: I, II, III, External In Semi-Auto Mode: I, II, III, AVR, AVL, AVF, V, External (12 lead compatibility)
  • ECG Gain (default): 1 V output per 1 mV input ±5% (waveform automatically scaled to occupy ECG display window)
  • Gain (variable): 0.15 to 3.0 cm/mV ±20% (autoscaling disabled)
  • Frequency Response: 0.5-12 Hz (display); 0.5-135 Hz (Output to External Monitor)
  • Defibrillator Protection: Discharge level ≤ 360 J (trace returns to screen in 5 sec max)
  • ESIS: Automatic suppression with internal ECG amplifier
]]>