Shop

Showing 13–18 of 49 results

DRAGER EVITA XL

DRAGER EVITA XL

Features

The Drager Evita XL ventilator is a feature-rich design that helps caregivers deliver optimal ventilation from implementation to the weaning process. The monitor quickly responds to individual patient requirements and ventilation situations, increasing patient comfort, and safety.

The Drager Evita XL Ventilator offers mask ventilation with NIV plus, which in many cases reduces the need for intubation. When intubation is necessary, the ventilator’s integrated CO2 monitoring helps caregivers ensure correct placement and metabolic stability. Select workflow support functions, including routine O2 suction or automatic P0.1 measurement, can also simplify clinical routines. A unique trolley system allows staff to easily maneuver the Drager Evita ventilator throughout the care facility.

  • Versatile unit responds quickly to individual patient requirements and changing ventilation situations.
  • Mask ventilation with NIV plus available in all modes with comprehensive monitoring and alarm adaptation.
  • Integrated CO2 monitoring helps verify correct intubation and metabolic stability.
  • Lung protection package offers low flow P/V maneuver to identify optimal-PEEP and pressure settings for lung protective ventilation.
  • Open breathing system with AutoFlow or PCV+ allows spontaneous breathing in all ventilation modes.
  • Workflow support functions streamline clinical routines.
  • NeoFlow offers flow measurement at the Y-piece for fast response to patient triggering, leakage adaptation, and precise volume delivery for neonates.
  • SmartCare / PS automated weaning system provides continuous vigilance for opportunities to reduce the level of ventilator support.
  • Automatic tube compensation supports respiratory independence during the weaning process.
  • Open breathing system with Mandatory Minute Ventilation ensures that patients, from neonates to adults, will receive the set minute volume, regardless of the spontaneous breathing level.
  • Maneuverable trolley for movement throughout care facility.
Category:
Share:

DRAGER INFINITY V500

DRAGER INFINITY V500

Features

The Drager Evita Infinity V500 can be used on adult, pediatric and neonatal patients. The Drager v500 is an advanced ventilation system that is used for acute respiratory support. Providing both invasive and Non-invasive ventilation along with comprehensive monitoring and treatment functions. The monitoring screen comes with an omnidirectional alarm bar, that can be seen from any point in the patient’s room. The Evita V500 Ventilator is recognized for its comprehensive patient -interface leakage. By compensating quickly by adjusting both triggers and termination points.

  • Lung diagnostic tools like Low Flow.
  • Volumetric CO2 Monitoring.
  • Weaning parameters.
  • Variable pressure support.
  • Non-invasive ventilation in all modes and all patient categories.
  • Data export via USB Interface.
  • Flexible screen configurations.
Category:
Share:

DRAGER SAVINA

DRAGER SAVINA

Features

The Drager Savina is a ventilator that can be used on a wide range of patients from pediatrics to adults. The System offers a variety of ventilation modes that allows for spontaneous breathing in all modes. With an internal turbine, there is no need for an air cylinder and external compressor anymore. The Savina was designed to be easy to read with a bright, high-resolution screen. The Savina offers both invasive and non-invasive ventilation. With the machine’s open breathing system with an integrated alarm system making it a flexible system that can easily be adapted for each patients ventilation situation.

  • Advanced, high-quality ICU ventilator that offers excellent ventilation performance combined with easy operation
  • Designed for both adult and pediatric ventilation, the Savina provides advanced therapy at any acuity level
  • Comprehensive safety concept
  • Increased flexibility
  • Supports the recovery process at every stage
  • Simple and effective user interface
Category:
Share:

ERUMO SARNS 8000

ERUMO SARNS 8000

Features

The Sarns Modular Perfusion System 8000 is a compact heart-lung machine commonly used in cardiac surgery. Equipped with Terumo’s proven technology, the cardiopulmonary bypass pump is designed with patient safety and user needs in mind. With the improved versatility, adaptability, and customizability, the Perfusion System 8000 is well-suited to be used in the extracorporeal circulation of blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass applications.

The Terumo Sarns Modular Perfusion System 8000 is a versatile and compact heart-lung machine designed for use in cardiac surgery. The modular design and built-in features of the System 8000 enable the platform to be configured for current and future needs in the field. The modular features of the System 8000 enable the cardiopulmonary bypass pump to be set up in a variety of configurations. The System 8000 is available in a four-pump or a five-pump base with an option for acquiring a built-in centrifugal pump. The Perfusion System 8000 can be configured based on new protocols and individual patient needs. The cardiopulmonary bypass pump’s flexibility enables the users to manage a specific case based on the definition of safety connection and responses, the utilization of the Central Control Monitor, and the implementation of the machine’s built-in Sarns capabilities. The heart-lung machine also features a state-of-the-art Central Control Monitor. The Central Control Monitor is a high-resolution touchscreen computer designed to be used as a safety monitor and the central interface for operating the machine.

 

  • Modular design
  • Four or five pump base
  • Roller or centrifugal pumps
  • Arterial and cardioplegia monitors for temperature, pressures and timers
  • Battery module
  • Electronic venous occluder
  • Pulse mode
  • Communications module for data acquisition
Share:

GE AESPIRE 7100

GE AESPIRE 7100

Features

The S/5 Aespire marks the introduction of the new Advanced Breathing System, the ABS™. Its design, based on your needs, is fully integrated into the workstation. Fewer parts and connections reduce the potential for leaks and misconnects, providing greater patient safety. Multi Absorber* canister facilitates fast, easy removal and replacement. Fully autoclavable, integrated electronics detect complete engagement or disengagement of the ABS. One step mechanical bag to vent switch requires no electronics.

Soma Tech Intl offers two different ventilator options in the GE Datex Ohmeda S/5 Anesthesia Machine. The GE Aespire can either have a 7100 ventilator or a 7900 ventilator. Both of these ventilators are microprocessor-based, electronically-control, and pneumatically-driven. The S/5 Aespire’s ventilators have built-in monitoring for inspired oxygen, airway pressure, and exhaled volume. These ventilators are designed to be used to aid in the delivery of anesthesia and are part of the GE Datex Ohmeda S/5 Aespire anesthesia machine.

7900 and 7100 Ventilator Safety Features

  • Dual redundant airway overpressure protection.
  • Volume over-delivery limits and protection.
  • Proprietary hose connections and fixed manifolds.
  • 10 VA electrical power limiting to potential oxygen enriched environment.
  • 150 psi burst overpressure protection.

Ventilator Monitoring Boards

The 7100 ventilator is accompanied by a Ventilator Monitoring Board (VMB) which serves as the interface between the ventilator’s control board and the breathing system sensors and switches. It passes different switch functions through to the ventilator control module and provides power to the task light. Respiratory gas flow, to and from the patient, is monitored by measuring the differential pressure across a variable orifice in each flow sensor. The pressure transducers measure the differential pressure on the VMB.

The 7900 ventilator is equipped with an Enhanced Sensor Interface Board (ESIB) which is located under the tabletop. The ESIB serves as the interface between the ventilator CPU board and the breathing circuit sensors and several machine switches. It passes through various switch positions to the ventilator CPU board and provides an interface for the ACGO switch, the Bag/Vent switch, the canister release switch, control panel cover switch, CO2 bypass switch, and breathing circuit ID switches.

Ventilator Batteries

Both the 7100 and the 7900 ventilators on the S/5 Aespire have a sealed lead acid battery that is only used as back up power in case of power failure. The batteries will power each unit for about 30 minutes.

GE Datex Ohmeda S/5 Aespire Anesthesia Machine Features

  • Power up is quick and easy in your fast-paced environment.
  • Minimum 02 flow of 50 mL available with dual flow tubes, ensures accuracy in low flow situations.
  • Enhanced hose and cable management reduces disconnects and clutter.
  • Lightweight and compact for easy maneuverability.
  • Larger work surface for supplies and chart.
  • Two large drawers provide more storage.
  • Removable drawer insert conveniently stores small items.
  • Smooth, durable surfaces for cleaning ease.
Share:

GE AESPIRE 7900

GE AESPIRE 7900

Features

The GE Datex Ohmeda Aespire View is compact, durable, with easy to clean surfaces. It comes with a 12-inch ventilation display that showcases waveforms and alarm indicators. The Aespire offers both anesthesia gases and ventilation at the same time. The Aespire View uses the GE SmartVent 7900 as the ventilator system for the anesthesia machine. The ventilation system makes it easy to minimize the space in the ICU or operating room by combining the Ventilator and the anesthesia machine in one. The Aespire View also comes standard with GE’s advances Breathing System (ABS). This allows the anesthesia machine to work with low circuit volumes as well as low flow anesthesia.

  • Small breathing system volume rapidly response to fresh gas changes with the ABS (Advanced Breathing System).
  • Fewer parts to help prevent unwanted disconnects and leaks.
  • Bag-to-vent switch works without electronics in case of power failure.
  • Autoclavable and latex-free surfaces.
  • Optional EXChange and condenser.
  • Extra large work surface area.
  • Two storage drawers.
Share: